Solar inverter replacement and repair, including systems we didn't install
Most solar inverters last 10 to 15 years, and when one fails, the panels behind it stop producing electricity you can use. We find out whether yours can be repaired or needs replacing. A replacement typically costs £1,200 to £2,000 fitted, and we deal with your network operator for you.
How long does a solar inverter last?
Most inverters last somewhere between ten and fifteen years, against panels rated for twenty-five or more. So many systems will need a new inverter during the panels' lifetime, and on a system around a decade old it is one thing to check when generation falls away. Read how long solar panels last for the wider system lifespan.
Inverter warranties usually run 5 to 10 years, longer with an extended warranty. Before paying for anything, check the installation date and the warranty papers in your handover pack, because a unit still in warranty may be covered.
The signs are usually plain: an error code or a red or orange light on the inverter, a blank screen in daylight, or a monitoring app showing nothing on a bright day.
A system that looks dead may have a monitoring fault rather than a failed inverter. We check before recommending a replacement.

Is it the inverter?
What you can see, what it usually points to, and whether it can be put right. We check all of it on site.
| What you see | What it usually points to | Fixable? |
|---|---|---|
| Error code or red light on the inverter | The inverter has found a fault, in itself or in the panels and wiring feeding it | Yes, once diagnosed |
| Blank screen in daylight | No power reaching it, a tripped isolator or breaker, or a failed unit | Usually |
| It stopped during a power cut | Normal. Inverters must switch off when the mains goes, and wait at least 20 seconds after it returns before reconnecting | Should restart by itself |
| Still off once the power is back | A tripped breaker or isolator, or a fault the power cut showed up | Yes |
| Generation falling slowly over months | See servicing | |
| App shows nothing, inverter shows green | The monitoring connection may be at fault even though the inverter is working | Check monitoring |
A photo of the screen, including any error code, and of the label on the side of the inverter is usually enough to start. The slow-decline row is covered on our servicing and maintenance page; see solar panel repair for other faults.
Repair or replace?
We check where the fault lies before recommending a repair or a replacement.
Repair
When the fault can be fixed and the inverter has years left in it.
A failed system does not always mean a failed inverter. Damaged cables, burnt-out MC4 connectors, loose connections and faulty DC isolators are among the other faults we investigate; what can be repaired depends on the diagnosis.
Replace
When it is old, out of warranty, or failing again.
An inverter near the end of its ten to fifteen years and out of warranty is rarely worth a repair bill. A new one comes with a new warranty, and it is the moment to ask whether a hybrid inverter makes sense.
What a replacement costs
A replacement inverter typically costs £1,200 to £2,000 fitted, depending on its size and type.
The £1,200 to £2,000 home price includes the new inverter fitted and tested, an electrical certificate, updated MCS paperwork and the notification to the network operator required under G98 or G99. The price depends on inverter size; access and the ease of the swap depend on where and how it is mounted.
Servicing, repairs, cleaning and bird proofing are charged with VAT at the standard rate; new home solar panel and battery installations are zero-rated (0% VAT) until 31 March 2027, then 5%. Commercial work is charged with VAT at the standard rate.

We keep some inverters in stock and source others for the job, matched to your panels and your connection. We fit all the major inverter brands, including SMA, Solis, Sunsynk, Solax and Fox ESS.
For commercial systems, the price depends on inverter size, how easy the swap is, and where and how the unit is mounted. A 10 kW inverter and a 100 kW inverter are not the same job.
Do I need a G99 compliant inverter?
Any inverter fitted today has to meet the current connection standard, and it should be listed on the ENA Type Test Register. Which standard depends on size. Up to 16 amps per phase, about 3.68 kW on a normal single-phase home supply, it is EREC G98. Above that, it is EREC G99.
A like-for-like swap does not usually need a new application. The ENA's G99 guidance treats replacing a failed inverter with an equivalent one as maintenance: the rest of the system does not have to be brought up to the new rules, but the new inverter itself has to comply with the latest G99. For homes connected under the old rules, G83, G98 says that replacing a significant part such as the inverter means the system has to meet G98.
A bigger inverter can change the route. The 16 amp limit is the total of every inverter on your supply, a battery inverter included. Swap a 3.6 kW inverter for a 5 kW hybrid and a system that was a G98 notification can become a G99 application, which has to be approved before the work.
Your network operator can ask for tests. Under G98 it can ask for compliance tests after any replacement that could affect the system, and operators ask to be told about changes to an existing installation. Electricity North West, the network operator for Warrington and most of the North West, says so in its G98 and G99 guidance. We deal with your network operator and handle any notifications the work needs.
The register is checked before anything is ordered. Manufacturers submit their test reports to the ENA Type Test Register, which moved to the ENA's Connect Direct service in April 2024. A model that is not on it makes the paperwork slower, so we check the replacement is listed before we order it.
On the Feed-in Tariff? Ofgem's rules say you must tell your FIT supplier about changes to the installation, including replacing equipment with a bigger or smaller capacity, or connecting a battery. Tell them when the work is done. Read our full guide to G98, G99 and DNO approval, or see what a G99 compliant inverter replacement involves.

Like for like, or a hybrid?
Where a replacement is needed we will also tell you whether a hybrid inverter is worth considering, because it opens up adding a battery later without a second round of work.
Like for like. The same job your old inverter did, matched to your panels. The simplest paperwork, because the size of the system on your connection does not change.
A hybrid inverter. One unit that runs the panels and a battery. Worth it if you might add a battery and your old inverter has to go anyway. If you never plan to add one, it is money you do not need to spend.
A bigger hybrid can take a home system over the G98 limit, so we check the connection before choosing one. More on adding a battery to the solar you have.
Inverter faults on a business site
On a commercial roof the inverter is often one of several, and one fault can leave a whole section of the array producing nothing while the site carries on buying everything from the grid. Tell us the system size, inverter brand and what has stopped working so we can discuss the next step. For ongoing monitoring and scheduled checks, see commercial solar O&M.
What we check and plan for commercial inverter work
- A diagnosis based on the fault, system size and access, with the visit priced after a phone conversation
- Risk assessment and method statement documents for roof work, inspections and jobs where the customer needs them
- Public and employer's liability insurance of £10 million, certificates provided
- The system drawings and design package checked where available, along with inverter and panel makes
- Working at height carried out safely, with the right access equipment for the roof
- Replacements checked against your G99 connection and the ENA Type Test Register before they are ordered
- Findings and next steps explained after the inspection
For planned maintenance across the whole system, see our commercial and agricultural O&M.
Accreditations
DB Energy is MCS certified and a member of RECC. Our electrical work is carried out under NICEIC registration, we are CHAS accredited, and our workmanship guarantee is insured through IWA.
MCS certified
RECC member
NICEIC registered
CHAS accredited
IWA insurance-backed guarantee
Service areas
We are based in Warrington and service solar systems for homes, businesses and farms across the UK. In the North West that includes Warrington, Liverpool, Manchester, Crewe, Runcorn, Widnes and Oldham, and the whole of Cheshire, Greater Manchester, Merseyside and Lancashire. Further afield we already work in Scotland, Wales, London, the Midlands and the North East. Wherever you are, we deal with your network operator and handle any notifications your work requires.
Questions about inverters
How long does a solar inverter last?
Most solar inverters last 10 to 15 years, while panels are rated for 25 or more, so many systems need a replacement during their life. If yours is around ten years old and generation has stopped, the inverter is one thing to check, alongside the connections and system design. An error code, a red light or a blank screen in daylight can help with diagnosis.
How much does it cost to replace a solar inverter?
Our home inverter replacements typically cost £1,200 to £2,000 fitted, depending on the inverter's size and type. The home price includes a new inverter fitted and tested, an electrical certificate, updated MCS paperwork and any required G98/G99 network operator notification. Commercial inverter work is priced by unit size, mounting and ease of replacement; repairs and commercial work carry VAT at the standard rate.
Do I need a G99 compliant inverter when I replace mine?
The replacement must meet the current standard for your system's size: EREC G98 up to 16 amps per phase (about 3.68 kW single phase), EREC G99 above that. A like-for-like swap does not usually need a new application, but a larger or hybrid inverter can move a system into G99 and require approval before work. We check the ENA Type Test Register and handle the network operator notification the change needs.
Should I repair or replace my solar inverter?
Repair if the fault can be fixed and the inverter still has years left, or if it turns out not to be the inverter at all, such as a tripped breaker or a wiring fault. Replace if it is near the end of its 10 to 15 years, out of warranty or failing again. We tell you which you are looking at before any work starts.
Is a failed inverter covered by its warranty?
It may be. Inverter warranties usually run 5 to 10 years, longer if an extended warranty was bought, so check the installation date and the warranty papers before paying for a replacement. The model and serial number are on the label on the side of the inverter, and you will need both for a claim.
Do I need to tell my Feed-in Tariff supplier if I replace the inverter?
Yes. Ofgem's rules say Feed-in Tariff generators must tell their FIT supplier about modifications to an accredited installation, including replacing equipment with a bigger or smaller capacity, connecting a battery, or replacing a meter. Tell them once the work is done, and keep the commissioning paperwork we give you.
Can I swap to a hybrid inverter so I can add a battery later?
Yes, and if your old inverter has to be replaced anyway it is the right moment to do it, because a hybrid runs both the panels and a battery and avoids a second round of work. If you never plan to add a battery, a like-for-like replacement is simpler. A larger hybrid can take a home system over the G98 limit, so we check your connection first.
Why has my inverter stopped after a power cut?
Grid-connected inverters switch off when the mains supply goes and wait at least 20 seconds after power returns before reconnecting. If yours is still off or showing an error in daylight, send us a photo of the display and leave electrical checks to a professional.
Send us a photo of the inverter
A photo of the screen, including any error code, and the label on the side of the inverter is usually enough to start. We will tell you whether it looks like a repair, a replacement, or nothing to do with the inverter at all.
Include the error code and the label on the inverter if you can photograph them safely.